Copper TubeAdhesiveBall ValveBlast Freezer and Blast Chiller Blower WheelBrazing TorchChiller (for AC)Coldroom PanelscompressorCompressor OilCondenserCondensing UnitCopper FittingsDigital Leak DetectorDigital ThermometerDrain Cleaning MachineElectronic Expansion ValveEvaporator and Unit CoolerExpanderExpansion JointExpansion ValveFilter Filter Drier & System ProtectorFin Straightener Fire Protection ProductsFlaring And Swaging ToolFlexible Metal HosesHVAC&R Chemicals SolutionsInsulationKitchen EquipmentsManeurope Comp. Selection Guide ManifoldManifold Charging HosesMAPP PROMicro ChannelMinicut I Pro and II ProMultideck Oil Regulator Oil ReservoirOil SeperatorPinch Off PlierPressure ControllerPressure GaugeQuick CouplerRachet WrenchRecovery TankRecovery UnitRefrigerantSight GlassSolenoid ValveSpring BenderSuction AccumulatorSupermarket & Kitchen EquipmentSwaging PunchTapeTee Extractor Sets 22124Temp ControllerTemperature Monitoring ControllerTPI Tube Bender Tube CutterV-Coil Housing CDU SystemsVacuum PumpValveVibration HoseWater PumpOthers

Lan Hoe Enterprise (1979) Sdn Bhd
24, Jalan 6/91,
Taman Shamelin Perkasa,
56100 Cheras,
Kuala Lumpur, Malaysia.
+603-9281 1323
+603-9282 4609


Pressure Control FD113ZU Series

Pressure Control FD113ZU Series

Pressure Control FD113ZU Series

Weight: 800 g
Emerson Pressure Control - FD113ZU Series

Features


 Size L x W x H = 19 x 14 x 6 (cm)
 Pressure range adjustable from 4 to 65
psid; Timer start pressure - timer stop pressure is 3 psid above timer
start pressure.
 An SPDT switch is used in the pressure portion of the control which allows the addition of a 'safe-light' when desired.
 Electronic Timer is Time-Adjustable from 20 to 150 seconds supply voltage - 24 to 240 Volt AC/ DC; Timing unaffected by voltage or ambient temperature variations.
 An SPDT Manual Reset Switch is used in the Timer Module; Upon time-out, the compressor is stopped and an alarm the
circuit is energized; To restart the compressor 
and deenergize the alarm circuit, the reset button is pushed.
 A factory installed Jumper allows the FD113 to be powered from a single source power; Should separate circuits to be desired for the timer and 'Lockout' switch, the Jumper can be removed. 


Specifications

 Agency approvals include : UL/CUL file number E85974, VDE 0631/0660, TUV, CE 73/23/EWG, CE 93/68/EWG



Emerson Pressure Controller Catalogue

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  



Switch to Mobile Version
available in